Use of fluorescence imaging and indocyanine green during colorectal surgery: Results of an intercontinental Delphi survey

Steven Wexner*, Mahmoud Abu-Gazala, Luigi Boni, Kenneth Buxey, Ronan Cahill, Thomas Carus, Sami Chadi, Manish Chand, Chris Cunningham, Sameh Hany Emile, Abe Fingerhut, Chi Chung Foo, Roel Hompes, Argyrios Ioannidis, Deborah S Keller, Joep Knol, Antonio Lacy, F Borja de Lacy, Gabriel Liberale, Joseph MartzIdo Mizrahi, Isacco Montroni, Neil Mortensen, Janice F Rafferty, Aaron S Rickles, Frederic Ris, Bashar Safar, Danny Sherwinter, Pierpaolo Sileri, Michael Stamos, Paul Starker, Jacqueline Van den Bos, Jun Watanabe, Joshua H Wolf, Shlomo Yellinek, Oded Zmora, Kevin P White, Fernando Dip, Raul J Rosenthal

*Corresponding author for this work

Research output: Contribution to journalArticleAcademicpeer-review

Abstract

BACKGROUND: Fluorescence imaging with indocyanine green is increasingly being used in colorectal surgery to assess anastomotic perfusion, and to detect sentinel lymph nodes.

METHODS: In this 2-round, online, Delphi survey, 35 international experts were asked to vote on 69 statements pertaining to patient preparation and contraindications to fluorescence imaging during colorectal surgery, indications, technical aspects, potential advantages/disadvantages, and effectiveness versus limitations, and training and research. Methodological steps were adopted during survey design to minimize risk of bias.

RESULTS: More than 70% consensus was reached on 60 of 69 statements, including moderate-strong consensus regarding fluorescence imaging's value assessing anastomotic perfusion and leak risk, but not on its value mapping sentinel nodes. Similarly, although consensus was reached regarding most technical aspects of its use assessing anastomoses, little consensus was achieved for lymph-node assessments. Evaluating anastomoses, experts agreed that the optimum total indocyanine green dose and timing are 5 to 10 mg and 30 to 60 seconds pre-evaluation, indocyanine green should be dosed milligram/kilogram, lines should be flushed with saline, and indocyanine green can be readministered if bright perfusion is not achieved, although how long surgeons should wait remains unknown. The only consensus achieved for lymph-node assessments was that 2 to 4 injection points are needed. Ninety-six percent and 100% consensus were reached that fluorescence imaging will increase in practice and research over the next decade, respectively.

CONCLUSION: Although further research remains necessary, fluorescence imaging appears to have value assessing anastomotic perfusion, but its value for lymph-node mapping remains questionable.

Original languageEnglish
Pages (from-to)S38-S45
Number of pages8
JournalSurgery
Volume172
Issue number6
DOIs
Publication statusPublished - Dec 2022

Keywords

  • Humans
  • Indocyanine Green
  • Colorectal Surgery
  • Optical Imaging
  • Sentinel Lymph Node Biopsy
  • Digestive System Surgical Procedures

Cite this