The effect of electro-anatomical mapping on the success rate and fluoroscopy time in supra-ventricular tachycardia ablation in children: single centre retrospective study

Robin A Bertels*, Maud W Françoijs, Catharina W Averdieck, Janneke A E Kammeraad, Luc H Filippini, Charlotte C A de Kezel, Stefan Frerich, Zina Fejzic, Frederik A du Plessis, Lucas A J Rammeloo, Irene M Kuipers, Nico A Blom

*Corresponding author for this work

Research output: Contribution to journalArticleAcademicpeer-review

Abstract

AIMS: To evaluate the effect of electro-anatomical mapping on success rate and fluoroscopy time in ablation of supraventricular tachycardia substrates in a large group of children. METHODS: Patients referred from multiple centres in the Netherlands and who received a first ablation for supraventricular tachycardia substrates in the Leiden University Medical Center between 2014 and 2020 were included in this retrospective cohort study. They were divided in procedures in patients with fluoroscopy and procedures in patients using electro-anatomical mapping. RESULTS: Outcomes of ablation of 373 electro-anatomical substrates were analysed. Acute success rate in the fluoro-group (n = 170) was 95.9% compared to 94.5% in the electro-anatomical mapping group (n = 181) (p = 0.539); recurrence rate was 6.1% in the fluoro-group and 6.4% in the electro-anatomical mapping group (p = 0.911) after a 12-months follow-up. Redo-ablations were performed in 12 cases in the fluoro-group and 10 cases in the electro-anatomical mapping group, with a success rate of 83.3% versus 80.0%, resulting in an overall success rate of 95.9% in the fluoro-group and 92.8% in the electro-anatomical mapping group (p = 0.216) after 12 months. Fluoroscopy time and dose area product decreased significantly from 16.00 ± 17.75 minutes (median ± interquartile range) to 2.00 ± 3.00 minutes (p = 0.000) and 210.5 µGym ± 249.3 to 32.9 µGym ± 78.6 (p = 0.000), respectively. In the fluoro-group, four complications occurred (2.0%) and in the electro-anatomical mapping group no complications occurred. CONCLUSION: These results demonstrate that ablations of supraventricular tachycardia substrates in children remain a highly effective and safe treatment after the introduction of electro-anatomical mapping as a standard of care, while significantly reducing fluoroscopy time and dose area product.
Original languageEnglish
Pages (from-to)1-6
Number of pages6
JournalCardiology in the Young
DOIs
Publication statusE-pub ahead of print - 11 Dec 2023

Keywords

  • Supra-ventricular tachycardia
  • ablation
  • child
  • electro-anatomical mapping
  • non-fluoroscopy

Cite this