TY - JOUR
T1 - Results of a diagnostic imaging audit in a randomised clinical trial in rectal cancer highlight the importance of careful planning and quality control
AU - Prata, Ilaria
AU - Eriksson, Martina
AU - Krdzalic, Jasenko
AU - Kranenbarg, Elma Meershoek-Klein
AU - Roodvoets, Annet G H
AU - Beets-Tan, Regina
AU - van de Velde, Cornelis J H
AU - van Etten, Boudewijn
AU - Hospers, Geke A P
AU - Glimelius, Bengt
AU - Nilsson, Per J
AU - Marijnen, Corrie A M
AU - Peeters, Koen C M J
AU - Blomqvist, Lennart K
PY - 2023/11/24
Y1 - 2023/11/24
N2 - BACKGROUND: Magnetic resonance (MR) imaging is the modality used for baseline assessment of locally advanced rectal cancer (LARC) and restaging after neoadjuvant treatment. The overall audited quality of MR imaging in large multicentre trials on rectal cancer is so far not routinely reported. MATERIALS AND METHODS: We collected MR images obtained within the Rectal Cancer And Pre-operative Induction Therapy Followed by Dedicated Operation (RAPIDO) trial and performed an audit of the technical features of image acquisition. The required MR sequences and slice thickness stated in the RAPIDO protocol were used as a reference. RESULTS: Out of 920 participants of the RAPIDO study, MR investigations of 668 and 623 patients in the baseline and restaging setting, respectively, were collected. Of these, 304/668 (45.5%) and 328/623 (52.6%) MR images, respectively, fulfilled the technical quality criteria. The main reason for non-compliance was exceeding slice thickness 238/668, 35.6% in the baseline setting and 162/623, 26.0% in the restaging setting. In 166/668, 24.9% and 168/623, 27.0% MR images in the baseline and restaging setting, respectively, one or more of the required pulse sequences were missing. CONCLUSION: Altogether, 49.0% of the MR images obtained within the RAPIDO trial fulfilled the image acquisition criteria required in the study protocol. High-quality MR imaging should be expected for the appropriate initial treatment and response evaluation of patients with LARC, and efforts should be made to maximise the quality of imaging in clinical trials and in clinical practice. CRITICAL RELEVANCE STATEMENT: This audit highlights the importance of adherence to MR image acquisition criteria for rectal cancer, both in multicentre trials and in daily clinical practice. High-resolution images allow correct staging, treatment stratification and evaluation of response to neoadjuvant treatment. KEY POINTS: - Complying to MR acquisition guidelines in multicentre trials is challenging. - Neglection on MR acquisition criteria leads to poor staging and treatment. - MR acquisition guidelines should be followed in trials and clinical practice. - Researchers should consider mandatory audits prior to study initiation.
AB - BACKGROUND: Magnetic resonance (MR) imaging is the modality used for baseline assessment of locally advanced rectal cancer (LARC) and restaging after neoadjuvant treatment. The overall audited quality of MR imaging in large multicentre trials on rectal cancer is so far not routinely reported. MATERIALS AND METHODS: We collected MR images obtained within the Rectal Cancer And Pre-operative Induction Therapy Followed by Dedicated Operation (RAPIDO) trial and performed an audit of the technical features of image acquisition. The required MR sequences and slice thickness stated in the RAPIDO protocol were used as a reference. RESULTS: Out of 920 participants of the RAPIDO study, MR investigations of 668 and 623 patients in the baseline and restaging setting, respectively, were collected. Of these, 304/668 (45.5%) and 328/623 (52.6%) MR images, respectively, fulfilled the technical quality criteria. The main reason for non-compliance was exceeding slice thickness 238/668, 35.6% in the baseline setting and 162/623, 26.0% in the restaging setting. In 166/668, 24.9% and 168/623, 27.0% MR images in the baseline and restaging setting, respectively, one or more of the required pulse sequences were missing. CONCLUSION: Altogether, 49.0% of the MR images obtained within the RAPIDO trial fulfilled the image acquisition criteria required in the study protocol. High-quality MR imaging should be expected for the appropriate initial treatment and response evaluation of patients with LARC, and efforts should be made to maximise the quality of imaging in clinical trials and in clinical practice. CRITICAL RELEVANCE STATEMENT: This audit highlights the importance of adherence to MR image acquisition criteria for rectal cancer, both in multicentre trials and in daily clinical practice. High-resolution images allow correct staging, treatment stratification and evaluation of response to neoadjuvant treatment. KEY POINTS: - Complying to MR acquisition guidelines in multicentre trials is challenging. - Neglection on MR acquisition criteria leads to poor staging and treatment. - MR acquisition guidelines should be followed in trials and clinical practice. - Researchers should consider mandatory audits prior to study initiation.
KW - Audit
KW - Image acquisition protocol
KW - Magnetic resonance imaging
KW - Rectal cancer
U2 - 10.1186/s13244-023-01552-0
DO - 10.1186/s13244-023-01552-0
M3 - (Systematic) Review article
SN - 1869-4101
VL - 14
JO - Insights into Imaging
JF - Insights into Imaging
IS - 1
M1 - 206
ER -