TY - JOUR
T1 - Replacing an Implant-Based with a DIEP Flap Breast Reconstruction
T2 - Breast Sensation and Quality of Life
AU - van Rooij, Joep A. F.
AU - Bijkerk, Ennie
AU - van der Hulst, Rene R. J. W.
AU - van Kuijk, Sander M. J.
AU - Tuinder, Stefania M. H.
PY - 2023/8/1
Y1 - 2023/8/1
N2 - Background:In this cohort study, the authors compared breast sensation and quality of life (QoL) after replacement of an implant-based breast reconstruction with a deep inferior epigastric perforator (DIEP) flap reconstruction in a singular sample of women. Methods:Women with implant-based breast reconstruction before their DIEP flap were included. Women formed their own control. Breast sensation was measured using Semmes-Weinstein monofilaments. QoL was evaluated using BREAST-Q questionnaires. Preoperative (T0) sensation and QoL were compared with postoperative values at 6 months (T1), at 12 months (T2), and at maximum follow-up (Tmax, sensation only). A linear mixed effects regression was used for Semmes-Weinstein monofilaments measurements; a paired samples t test was used for BREAST-Q scores. Most women chose replacement of their implant by a DIEP flap because of implant-related complaints. Results:Postoperative sensation decreased significantly compared with preoperative sensation after T1 (mean, 5.1 months), T2 (mean, 14.6 months), and Tmax (mean, 17.6 months) for the total breast but recovers to preoperative levels for the native skin after an average of 1.5 years. Nerve coaptation positively influenced recovery of sensation. BREAST-Q scores increased significantly after 6 and 12 months over the domains Satisfaction with Breasts, Psychosocial Well-Being, Physical Well-Being of the Chest, and Sexual Well-Being. Scores decreased significantly in Physical Well-Being of the Abdomen after 6 months. Conclusion:Replacing an implant with a DIEP flap initially causes a decrease in overall breast sensation, gradually recovering to preoperative levels for native skin, and can significantly increase QoL with the right indication. Superior recovery of sensation and QoL may be obtained by accompanying the DIEP flap with nerve coaptation.
AB - Background:In this cohort study, the authors compared breast sensation and quality of life (QoL) after replacement of an implant-based breast reconstruction with a deep inferior epigastric perforator (DIEP) flap reconstruction in a singular sample of women. Methods:Women with implant-based breast reconstruction before their DIEP flap were included. Women formed their own control. Breast sensation was measured using Semmes-Weinstein monofilaments. QoL was evaluated using BREAST-Q questionnaires. Preoperative (T0) sensation and QoL were compared with postoperative values at 6 months (T1), at 12 months (T2), and at maximum follow-up (Tmax, sensation only). A linear mixed effects regression was used for Semmes-Weinstein monofilaments measurements; a paired samples t test was used for BREAST-Q scores. Most women chose replacement of their implant by a DIEP flap because of implant-related complaints. Results:Postoperative sensation decreased significantly compared with preoperative sensation after T1 (mean, 5.1 months), T2 (mean, 14.6 months), and Tmax (mean, 17.6 months) for the total breast but recovers to preoperative levels for the native skin after an average of 1.5 years. Nerve coaptation positively influenced recovery of sensation. BREAST-Q scores increased significantly after 6 and 12 months over the domains Satisfaction with Breasts, Psychosocial Well-Being, Physical Well-Being of the Chest, and Sexual Well-Being. Scores decreased significantly in Physical Well-Being of the Abdomen after 6 months. Conclusion:Replacing an implant with a DIEP flap initially causes a decrease in overall breast sensation, gradually recovering to preoperative levels for native skin, and can significantly increase QoL with the right indication. Superior recovery of sensation and QoL may be obtained by accompanying the DIEP flap with nerve coaptation.
KW - PERFORATOR FLAPS
KW - SENSORY RECOVERY
KW - MASTECTOMY
KW - SENSIBILITY
KW - IMPROVES
KW - INFERIOR
U2 - 10.1097/PRS.0000000000010315
DO - 10.1097/PRS.0000000000010315
M3 - Article
C2 - 36827485
SN - 0032-1052
VL - 152
SP - 293
EP - 304
JO - Plastic and Reconstructive Surgery
JF - Plastic and Reconstructive Surgery
IS - 2
ER -