Arbitration of discrepant BI-RADS 0 recalls by a third reader at screening mammography lowers recall rate but not the cancer detection rate and sensitivity at blinded and non-blinded double reading

E.G. Klompenhouwer*, R.J.P. Weber, A.C. Voogd, G.J. den Heeten, L.J.A. Strobbe, M.J.M. Broeders, V.C.G. Tjan-Heijnen, L.E.M. Duijm

*Corresponding author for this work

Research output: Contribution to journalArticleAcademicpeer-review

Abstract

Purpose: To evaluate the characteristics of low suspicion lesions (BI-RADS 0) at blinded and non-blinded double reading of screening mammograms and to determine the potential effect of arbitration of discrepant BI-RADS 0 recalls by a third reader on screening outcome. Methods: We included a series of 84,927 consecutive digital screening mammograms, double read in a blinded (43,184 screens) or non-blinded (41,743 screens) fashion, between July 2009 and July 2011. Discrepant readings were routinely recalled for further evaluation. During 2 years of follow-up, radiology, surgical and pathology reports were collected of all recalled women. Arbitration of discrepant BI-RADS 0 recalls (only one radiologist assigning a BI-RADS 0 score) was retrospectively performed by a third screening radiologist. Results: At blinded and non-blinded double reading, 32.0% and 32.5% of recalls were assigned BI-RADS 0 with a positive predictive value (PPV) of 7.2% and 6.8%, respectively. Compared to non-blinded double reading, BI-RADS 0 recalls at blinded double reading showed a higher discrepancy rate (9.0 versus 4.3 per 1000 screens, p <0.001) and false positive recall rate (10.1 versus 8.4 per 1000 screens, p = 0.012). Arbitration of discrepant BI-RADS 0 recalls would have significantly lowered recall rate (from 3.4% to 2.8% at blinded double reading, p <0.001, and from 2.8% to 2.5% at non-blinded double reading, p = 0.008), without a decrease in cancer detection rate (from 7.5% to 7.3%, p = 0.751, and from 6.6% to 6.5%, p = 0.832, respectively) and program sensitivity (from 83.2% to 81.2%, p = 0.453, and from 76.0% to 74.6%, p = 0.667, respectively). Arbitration would have significantly increased the PPV at blinded double reading (from 22.3% to 26.3%, p = 0.015). Conclusion: We advise arbitration of discrepant BI-RADS 0 recalls, at (non-) blinded double reading of screening mammograms, to reduce recall rates and improve the PPV of recall at blinded double reading.
Original languageEnglish
Pages (from-to)601-607
JournalBreast
Volume24
Issue number5
DOIs
Publication statusPublished - 1 Jan 2015

Cite this