T1 - Accuracy and precision of vessel area assessment: Manual versus automatic lumen delineation based on full-width at half-maximum
AU - Merkx, Maarten A. G.
AU - Bescos, Javier Olivan
AU - Geerts, Liesbeth
AU - Bosboom, E. Marielle H.
AU - van de Vosse, Frans N.
AU - Breeuwer, Marcel
PY - 2012/11
Y1 - 2012/11
N2 - Purpose: To evaluate the accuracy and precision of manual and automatic blood vessel diameter measurements, a quantitative comparison was conducted, using both phantom and clinical 3D magnetic resonance angiography (MRA) data. Since diameters are often manually measured, which likely is influenced by operator dependency, automatic lumen delineation, based on the full-width at half-maximum (FWHM), could improve these measurements. Materials and Methods: Manual and automatic diameter assessments were compared, using MRA data from a vascular phantom (geometry obtained with mu CT) and clinical MRA data. The diameters were manually assessed by 15 MRA experts, using both caliper and contour tools. To translate the experimental results to clinical practice, the precision obtained using phantom data was compared to the precision obtained with clinical data. Results: A diameter error 20%), even at high resolutions, while precision for the automatic method was high (error
AB - Purpose: To evaluate the accuracy and precision of manual and automatic blood vessel diameter measurements, a quantitative comparison was conducted, using both phantom and clinical 3D magnetic resonance angiography (MRA) data. Since diameters are often manually measured, which likely is influenced by operator dependency, automatic lumen delineation, based on the full-width at half-maximum (FWHM), could improve these measurements. Materials and Methods: Manual and automatic diameter assessments were compared, using MRA data from a vascular phantom (geometry obtained with mu CT) and clinical MRA data. The diameters were manually assessed by 15 MRA experts, using both caliper and contour tools. To translate the experimental results to clinical practice, the precision obtained using phantom data was compared to the precision obtained with clinical data. Results: A diameter error 20%), even at high resolutions, while precision for the automatic method was high (error
KW - magnetic resonance angiography
KW - blood vessel diameter
KW - full-width at half-maximum
KW - accuracy
KW - precision
KW - manual vs
KW - automatic
U2 - 10.1002/jmri.23752
DO - 10.1002/jmri.23752
M3 - Article
SN - 1053-1807
VL - 36
SP - 1186
EP - 1193
JO - Journal of Magnetic Resonance Imaging
JF - Journal of Magnetic Resonance Imaging
IS - 5
ER -