TY - JOUR
T1 - Detailed analysis of ventricular activation sequences during right ventricular apical pacing and left bundle branch block and the potential implications for cardiac resynchronization therapy
AU - Eschalier, Romain
AU - Ploux, Sylvain
AU - Lumens, Joost
AU - Whinnett, Zachary
AU - Varma, Niraj
AU - Meillet, Valentin
AU - Ritter, Philippe
AU - Jais, Pierre
AU - Haissaguerre, Michel
AU - Bordachar, Pierre
PY - 2015/1
Y1 - 2015/1
N2 - BACKGROUND Left bundle branch block (LBBB) leads to prolonged left ventricular (LV) total activation time (TAT) and ventricular electrical uncoupling (VEU; mean LV activation time minus mean right ventricular [RV] activation time); both have been shown to be preferential targets for cardiac resynchronization therapy (CRT). Whether right ventricular apical pacing (RVAP) produces similar ventricular activation patterns has not been well studied. OBJECTIVE The purpose of this study was to compare electrical ventricular activation patterns during RVAP and LBBB. METHODS We performed ECG mapping during sinus rhythm, RVAP, and CRT in 24 patients with LBBB. RESULTS We observed differences in the electrical activation pattern with RVAP compared to LBBB. During LBBB, RV activation occurred rapidly; in contrast, RV activation was prolonged during RVAP (46 +/- 21 ms vs 69 +/- 17 ms, P <.001). There was no significant difference in LVTAT; however, differences in conduction pattern were observed. During LBBB, LV activation was circumferential, whereas with RVAP, LV activation proceeded from apex to base. Differences in the number, size, and orientation of lines of stow conduction also were observed. With LBBB, VEU was nearly twice as long as during RVAP (73 +/- 12 ms vs 38 +/- 21 ms, P <.001). CRT resulted in a greater reduction in VEU relative to LBBB activation (P <.001). CONCLUSION RVAP produces significant differences in ventricular activation characteristics compared to LBBB. Significantly less VEU occurs with RVAP, and as a result CRT produces a smaller relative reduction in VEU. This may explain the finding that CRT appears to be more effective in patients with LBBB than in those who were upgraded because of high percentages of RV pacing.
AB - BACKGROUND Left bundle branch block (LBBB) leads to prolonged left ventricular (LV) total activation time (TAT) and ventricular electrical uncoupling (VEU; mean LV activation time minus mean right ventricular [RV] activation time); both have been shown to be preferential targets for cardiac resynchronization therapy (CRT). Whether right ventricular apical pacing (RVAP) produces similar ventricular activation patterns has not been well studied. OBJECTIVE The purpose of this study was to compare electrical ventricular activation patterns during RVAP and LBBB. METHODS We performed ECG mapping during sinus rhythm, RVAP, and CRT in 24 patients with LBBB. RESULTS We observed differences in the electrical activation pattern with RVAP compared to LBBB. During LBBB, RV activation occurred rapidly; in contrast, RV activation was prolonged during RVAP (46 +/- 21 ms vs 69 +/- 17 ms, P <.001). There was no significant difference in LVTAT; however, differences in conduction pattern were observed. During LBBB, LV activation was circumferential, whereas with RVAP, LV activation proceeded from apex to base. Differences in the number, size, and orientation of lines of stow conduction also were observed. With LBBB, VEU was nearly twice as long as during RVAP (73 +/- 12 ms vs 38 +/- 21 ms, P <.001). CRT resulted in a greater reduction in VEU relative to LBBB activation (P <.001). CONCLUSION RVAP produces significant differences in ventricular activation characteristics compared to LBBB. Significantly less VEU occurs with RVAP, and as a result CRT produces a smaller relative reduction in VEU. This may explain the finding that CRT appears to be more effective in patients with LBBB than in those who were upgraded because of high percentages of RV pacing.
KW - Cardiac resynchronization therapy
KW - Electrocardiography
KW - Electrical dyssynchrony
KW - Ventricular mapping
KW - Left bundle branch block
U2 - 10.1016/j.hrthm.2014.09.059
DO - 10.1016/j.hrthm.2014.09.059
M3 - Article
SN - 1547-5271
VL - 12
SP - 137
EP - 143
JO - Heart Rhythm
JF - Heart Rhythm
IS - 1
ER -