Automated and Semiautomated Segmentation of Rectal Tumor Volumes on Diffusion-Weighted MRI: Can It Replace Manual Volumetry?

Miriam M. van Heeswijk, Doenja M. J. Lambregts*, Joost J. M. van Griethuysen, Stanley Oei, Sheng-Xiang Rao, Carla A. M. de Graaff, Roy F. A. Vliegen, Geerard L. Beets, Nikos Papanikolaou, Regina G. H. Beets-Tan

*Corresponding author for this work

Research output: Contribution to journalArticleAcademicpeer-review

Abstract

Purpose: Diffusion-weighted imaging (DWI) tumor volumetry is promising for rectal cancer response assessment, but an important drawback is that manual per-slice tumor delineation can be highly time consuming. This study investigated whether manual DWI-volumetry can be reproduced using a (semi) automated segmentation approach. Methods and Materials: Seventy-nine patients underwent magnetic resonance imaging (MRI) that included DWI (highest b value [b1000 or b1100]) before and after chemoradiation therapy (CRT). Tumor volumes were assessed on b1000 (or b1100) DWI before and after CRT by means of (1) automated segmentation (by 2 inexperienced readers), (2) semiautomated segmentation (manual adjustment of the volumes obtained by method 1 by 2 radiologists), and (3) manual segmentation (by 2 radiologists); this last assessment served as the reference standard. Intraclass correlation coefficients (ICC) and Dice similarity indices (DSI) were calculated to evaluate agreement between different methods and observers. Measurement times (from a radiologist's perspective) were recorded for each method. Results: Tumor volumes were not significantly different among the 3 methods, either before or after CRT (P=. 08 to.92). ICCs compared to manual segmentation were 0.80 to 0.91 and 0.53 to 0.66 before and after CRT, respectively, for the automated segmentation and 0.91 to 0.97 and 0.61 to 0.75, respectively, for the semiautomated method. Interobserver agreement (ICC) pre and post CRT was 0.82 and 0.59 for automated segmentation, 0.91 and 0.73 for semiautomated segmentation, and 0.91 and 0.75 for manual segmentation, respectively. Mean DSI between the automated and semiautomated method were 0.83 and 0.58 pre-CRT and post-CRT, respectively; DSI between the automated and manual segmentation were 0.68 and 0.42 and 0.70 and 0.41 between the semiautomated and manual segmentation, respectively. Median measurement time for the radiologists was 0 seconds (pre-and post-CRT) for the automated method, 41 to 69 seconds (pre-CRT) and 60 to 67 seconds (post-CRT) for the semiautomated method, and 180 to 296 seconds (pre-CRT) and 84 to 91 seconds (post-CRT) for the manual method. Conclusions: DWI volumetry using a semiautomated segmentation approach is promising and a potentially time-saving alternative to manual tumor delineation, particularly for primary tumor volumetry. Once further optimized, it could be a helpful tool for tumor response assessment in rectal cancer.
Original languageEnglish
Pages (from-to)824-831
JournalInternational Journal of Radiation Oncology Biology Physics
Volume94
Issue number4
DOIs
Publication statusPublished - 15 Mar 2016

Cite this