Transcatheter aortic valve replacement with Lotus and Sapien 3 prosthetic valves: a systematic review and meta-analysis

Miroslaw Gozdek, Jakub Ratajczak, Adam Arndt, Kamil Zielinski, Michal Pasierski, Matteo Matteucci, Dario Fina, Federica Jiritano, Paolo Meani, Giuseppe Maria Raffa, Pietro Giorgio Malvindi, Michele Pilato, Domenico Paparella, Artur Slomka, Uri Landes, Ran Kornowski, Jacek Kubica, Roberto Lorusso, Piotr Suwalski, Mariusz Kowalewski*Thoracic Research Centre

*Corresponding author for this work

Research output: Contribution to journal(Systematic) Review article peer-review

Abstract

Background: Frequent occurrence of paravalvular leak (PVL) after transcatheter aortic valve replacement (TAVR) was the main concern with early-generation devices and focused technological improvements. Current systematic review and meta-analysis sought to compare outcomes of TAVR for severe native valve stenosis with next-generation devices: Lotus and Sapien 3.

Methods: Electronic databases were screened for studies comparing outcomes of TAVR with Lotus and Sapien 3. In a random-effects meta-analysis, the pooled incidence rates of procedural, clinical and functional outcomes according to VARC-2 definitions were assessed.

Results: Eleven observational studies including 2,836 patients (Lotus N=862 vs. Sapien 3 N=1,974) met inclusion criteria. No differences were observed regarding composite endpoints-device success and early safety. Similarly, 30-day mortality, major vascular complications, acute kidney injury and serious bleeding events were similar with both devices. Lotus valve demonstrated 35% reduction of the risk for mild PVL: risk ratio (RR) 0.65, 95% confidence interval (CI): 0.49-0.85, P=0.002; but there were no statistical differences with regard to moderate/severe PVL (RR 0.56, 95% CI: 0.18-1.77, P=0.320). Lotus valves produced significantly higher mean transaortic gradients: mean difference (MD) 0.88 mmHg, 95% CI, 0.24-1.53 mmHg, P=0.007; however, without translation into higher rate of prosthesis-patient mismatch (RR 1.10, 95% CI: 0.82-1.47, P=0.540). As compared to Sapien 3, Lotus device placement was associated with significantly higher rate of permanent pacemaker implantation (RR 2.30, 95% CI: 1.95-2.71, P

Conclusions: Lotus valve, as compared with Sapien 3, was associated with lower risk for PVL but higher risk for permanent pacemaker implantation and cerebrovascular events.

Original languageEnglish
Pages (from-to)893-906
Number of pages22
JournalJournal of Thoracic Disease
Volume12
Issue number3
DOIs
Publication statusPublished - Mar 2020

Keywords

  • Meta-analysis
  • Lotus
  • Sapien 3
  • transcatheter aortic valve replacement (TAVR)
  • PERMANENT PACEMAKER IMPLANTATION
  • INTERMEDIATE-RISK PATIENTS
  • PARAVALVULAR REGURGITATION
  • CLINICAL-OUTCOMES
  • HEART-VALVES
  • PREDICTORS
  • IMPACT
  • STENOSIS
  • MORTALITY
  • CALCIFICATION