Tracmor system for measuring walking energy expenditure.
Levine J, Melanson EL, Westerterp KR, Hill JO.
Endocrine Research Unit, Mayo Clinic, Rochester, MN 55905, USA. [email protected]
OBJECTIVE: Walking is an important mode of exercise and is likely to represent a major component of nonexercise activity thermogenesis. The question arises, how best to quantify walking-energy expenditure (EE) in free-living individuals. The triaxial accelerometer for movement registration (Tracmor) is a valid measure of body displacement and so we wanted to evaluate this tool for quantifying walking-EE. HYPOTHESIS: In this study, we test the hypothesis that walking-EE, measured in a Room Calorimeter, can be predicted from Tracmor output using a regression equation derived from a brief Tracmor/treadmill/Metabolic Cart protocol. DESIGN: First, 11 healthy subjects completed a 40-min procedure whereby they wore a Tracmor unit and walked on a treadmill at 0, 1, 2 and 3 mph while EE was measured using a Metabolic Cart. This allowed a regression equation to be defined for each subject to convert Tracmor output to EE. Each subject then entered a Room Calorimeter wearing the Tracmor Unit and walked at two self-selected velocities ('slow', 'fast') while EE was measured. 'Tracmor/regression equation' predictions of walking-EE were compared with Room Calorimeter measurements of walking-EE for the two velocities. RESULTS: The 'Tracmor/regression equation' prediction of EE for walking slowly was 6.36+/-1.67 kJ/min, and for walking fast it was 11.0+/-2.60 kJ/min. Room Calorimeter measurements were 6.43+/-1.85 and 10.9+/-3.03 kJ/min, respectively. The intraclass correlation coefficient for slow-paced walking was 0.93 (P<0.001), and for fast-paced walking it was 0.82 (P<0.005). CONCLUSIONS: When combined with laboratory measures of EE, the Tracmor accelerometer provides useful data on walking-EE and is applicable to free-living individuals
Levine J, Melanson EL, Westerterp KR, Hill JO.
Endocrine Research Unit, Mayo Clinic, Rochester, MN 55905, USA. [email protected]
OBJECTIVE: Walking is an important mode of exercise and is likely to represent a major component of nonexercise activity thermogenesis. The question arises, how best to quantify walking-energy expenditure (EE) in free-living individuals. The triaxial accelerometer for movement registration (Tracmor) is a valid measure of body displacement and so we wanted to evaluate this tool for quantifying walking-EE. HYPOTHESIS: In this study, we test the hypothesis that walking-EE, measured in a Room Calorimeter, can be predicted from Tracmor output using a regression equation derived from a brief Tracmor/treadmill/Metabolic Cart protocol. DESIGN: First, 11 healthy subjects completed a 40-min procedure whereby they wore a Tracmor unit and walked on a treadmill at 0, 1, 2 and 3 mph while EE was measured using a Metabolic Cart. This allowed a regression equation to be defined for each subject to convert Tracmor output to EE. Each subject then entered a Room Calorimeter wearing the Tracmor Unit and walked at two self-selected velocities ('slow', 'fast') while EE was measured. 'Tracmor/regression equation' predictions of walking-EE were compared with Room Calorimeter measurements of walking-EE for the two velocities. RESULTS: The 'Tracmor/regression equation' prediction of EE for walking slowly was 6.36+/-1.67 kJ/min, and for walking fast it was 11.0+/-2.60 kJ/min. Room Calorimeter measurements were 6.43+/-1.85 and 10.9+/-3.03 kJ/min, respectively. The intraclass correlation coefficient for slow-paced walking was 0.93 (P<0.001), and for fast-paced walking it was 0.82 (P<0.005). CONCLUSIONS: When combined with laboratory measures of EE, the Tracmor accelerometer provides useful data on walking-EE and is applicable to free-living individuals
Original language | English |
---|---|
Pages (from-to) | 1176-1180 |
Number of pages | 4 |
Journal | European Journal of Clinical Nutrition |
Volume | 57 |
Issue number | 9 |
DOIs | |
Publication status | Published - 1 Jan 2003 |