TY - JOUR
T1 - The use of a (non-) balloon guide catheter in endovascular stroke treatment, a registry of real-life use and nationwide questionnaire
AU - Knapen, R. R.M.M.
AU - Celen, M.
AU - Benali, F.
AU - van Oostenbrugge, R. J.
AU - van Zwam, W. H.
AU - van der Leij, C.
N1 - Publisher Copyright:
© 2024 The Author(s)
PY - 2024/12/1
Y1 - 2024/12/1
N2 - Introduction: Despite literature suggesting benefits of a balloon guide catheter (BGC) in stroke thrombectomy, BGCs are not routinely used. This study aimed to get insights in the use of a BGC and the reasons (not) to inflate the balloon. Methods: Data were used of the Maastricht Stroke Quality Registry (MaSQ-Registry), a prospective registry for quality purposes of stroke patients treated between September 2020-February 2023. Additionally, a Dutch nationwide questionnaire was sent among all stroke treating physicians of the Dutch Society of Interventional Radiology (NVIR). Information on the use and reasons for selecting a (non-)BGC and using the BGC was collected. Results: Out of 511 patients registered in the MaSQ-Registry, 458 were included. In 69% (n=317) of the patients a BGC was used; in 68% (n=214) the balloon was not inflated. In 95% of the posterior circulation occlusions a non-BGC was used. In total 47 treating physicians from sixteen stroke centers responded to the questionnaire. 51% (n=24) preferred a non-BGC and 30% (n=14) never used a BGC. 52% and 18% of the BGC-users estimated they inflate the balloon in 80-100% and 0-20% of the times, respectively. The main reasons reported for not inflating the balloon were when the BGC was occlusive (47%) or not placeable (34%) in the carotid artery. Conclusion: This study shows variation in the use of (non-)BGC use with and without inflated balloon among treating physicians in the Netherlands, highlighting current limited consensus regarding the use of (non-)BGCs among stroke treating physicians.
AB - Introduction: Despite literature suggesting benefits of a balloon guide catheter (BGC) in stroke thrombectomy, BGCs are not routinely used. This study aimed to get insights in the use of a BGC and the reasons (not) to inflate the balloon. Methods: Data were used of the Maastricht Stroke Quality Registry (MaSQ-Registry), a prospective registry for quality purposes of stroke patients treated between September 2020-February 2023. Additionally, a Dutch nationwide questionnaire was sent among all stroke treating physicians of the Dutch Society of Interventional Radiology (NVIR). Information on the use and reasons for selecting a (non-)BGC and using the BGC was collected. Results: Out of 511 patients registered in the MaSQ-Registry, 458 were included. In 69% (n=317) of the patients a BGC was used; in 68% (n=214) the balloon was not inflated. In 95% of the posterior circulation occlusions a non-BGC was used. In total 47 treating physicians from sixteen stroke centers responded to the questionnaire. 51% (n=24) preferred a non-BGC and 30% (n=14) never used a BGC. 52% and 18% of the BGC-users estimated they inflate the balloon in 80-100% and 0-20% of the times, respectively. The main reasons reported for not inflating the balloon were when the BGC was occlusive (47%) or not placeable (34%) in the carotid artery. Conclusion: This study shows variation in the use of (non-)BGC use with and without inflated balloon among treating physicians in the Netherlands, highlighting current limited consensus regarding the use of (non-)BGCs among stroke treating physicians.
KW - Acute ischemic stroke (AIS)
KW - Balloon guide catheter (BGC)
KW - Intra-arterial thrombectomy (IAT)
KW - Stroke – Endovascular treatment (EVT)
KW - Survey
U2 - 10.1016/j.jstrokecerebrovasdis.2024.108033
DO - 10.1016/j.jstrokecerebrovasdis.2024.108033
M3 - Article
SN - 1052-3057
VL - 33
JO - Journal of Stroke & Cerebrovascular Diseases
JF - Journal of Stroke & Cerebrovascular Diseases
IS - 12
M1 - 108033
ER -