TY - JOUR
T1 - The paradoxical stimulation by a reversible thrombin inhibitor of thrombin generation in plasma measured with thrombinography is caused by alpha(2)-macroglobulin-thrombin
AU - Wagenvoord, R. J.
AU - Deinum, J.
AU - Elg, M.
AU - Hemker, H. C.
PY - 2010/6
Y1 - 2010/6
N2 - Background. Thrombin generation (TG) in plasma can be monitored continuously with a fluorogenic thrombin substrate using calibrated automated thrombinography ( CAT). In the presence of low concentrations of a reversible direct thrombin inhibitor (DTI), CAT shows an unexpected effect: the endogenous thrombin potential (ETP) increases at low concentrations of the inhibitor to subsequently decrease concentration dependently at higher concentrations (> approximately 100 nM). Objectives. To find an explanation for this phenomenon, we measured the concentrations of free thrombin and alpha(2)-macroglobulin- thrombin complex (alpha 2MT) with a sub-sampling technique in the presence of AR-H067637, a selective DTI. Results. At all concentrations of the DTI there was a gradual dose-dependent decrease in the concentration of free, not-inhibited thrombin but a transient increase in free alpha 2MT due to competition of thrombin and alpha 2MT for the inhibitor. Because the CAT technique uses an algorithm to subtract alpha 2MT activity from the total amidolytic activity, this transient increase in alpha 2MT activity is not subtracted and erroneously attributed to thrombin itself. Conclusions. This study explains the spurious increase in ETP observed at low DTI concentrations. The results obtained in plasma were corroborated by observations in a thrombin generating system reconstituted with purified factors. In practise, the effect of DTIs on TG can be reliably evaluated from the area under the curve till time-to-peak.
AB - Background. Thrombin generation (TG) in plasma can be monitored continuously with a fluorogenic thrombin substrate using calibrated automated thrombinography ( CAT). In the presence of low concentrations of a reversible direct thrombin inhibitor (DTI), CAT shows an unexpected effect: the endogenous thrombin potential (ETP) increases at low concentrations of the inhibitor to subsequently decrease concentration dependently at higher concentrations (> approximately 100 nM). Objectives. To find an explanation for this phenomenon, we measured the concentrations of free thrombin and alpha(2)-macroglobulin- thrombin complex (alpha 2MT) with a sub-sampling technique in the presence of AR-H067637, a selective DTI. Results. At all concentrations of the DTI there was a gradual dose-dependent decrease in the concentration of free, not-inhibited thrombin but a transient increase in free alpha 2MT due to competition of thrombin and alpha 2MT for the inhibitor. Because the CAT technique uses an algorithm to subtract alpha 2MT activity from the total amidolytic activity, this transient increase in alpha 2MT activity is not subtracted and erroneously attributed to thrombin itself. Conclusions. This study explains the spurious increase in ETP observed at low DTI concentrations. The results obtained in plasma were corroborated by observations in a thrombin generating system reconstituted with purified factors. In practise, the effect of DTIs on TG can be reliably evaluated from the area under the curve till time-to-peak.
KW - calibrated automated thrombinography
KW - reversible direct thrombin inhibitors
KW - sub-sampling technique
KW - thrombin generation
U2 - 10.1111/j.1538-7836.2010.03822.x
DO - 10.1111/j.1538-7836.2010.03822.x
M3 - Article
C2 - 20180821
SN - 1538-7933
VL - 8
SP - 1281
EP - 1289
JO - Journal of Thrombosis and Haemostasis
JF - Journal of Thrombosis and Haemostasis
IS - 6
ER -