N2 - Background and Objectives: The understanding of high body mass index (BMI) and outcomes after Left Ventricular Assist Device (LVAD) implantation continues to evolve and the relationship has not been established yet. In this study, we investigated the effects of obesity (BMI > 30 kg/m2) on post-LVAD implantation outcomes. HeartWare LVAD and Heart Mate III LVAD were implanted. The primary outcome that was measured was mortality (in-hospital and on follow-up). The secondary outcomes that were measured were major adverse events. Materials and Methods: At our institution, the West German Heart and Vascular Center (Essen, Germany), from August 2010 to January 2020, a total of 210 patients received a long-term LVAD. Patients were stratified according to BMI ≥ 30 kg/m2 representing the obesity threshold. The first group (n = 162) had an average BMI of 24.2 kg/m2 (±2.9), and the second group (n = 48) had an average BMI of 33.9 kg/m2 (±3.2). Baseline demographics were analysed alongside comorbidities per group. Results: Overall mortality was not significantly different between the obese group (51.1% n = 24) and the nonobese group (55.2%, n = 85) (p = 0.619). The difference between the mean duration of survival of patients who expired after hospital discharge was insignificant (2.1 years ± 1.6, group 1; 2.6 years ± 1.5, group 2; p = 0.29). In-hospital mortality was unvaried between the two groups: group 1: n = 34 (44% out of overall group 1 deaths); group 2: n = 11 (45.8% out of overall group 2 deaths) (p > 0.05). Postoperative complications were unvaried between the obese and the non-obese group (all with p > 0.05). However, a significant difference was found with regards to follow-up neurological complications (18.5% vs. 37.8%, p = 0.01) and LVAD thrombosis (14.7% vs. 33.3%, p = 0.01), as both were higher in the obese population. Conclusion: Obesity does not form a barrier for LVAD implantation in terms of mortality (in-hospital and on follow up). However, a significantly higher incidence of follow-up LVAD thrombosis and neurological complications has been found in the obese group of patients.
AB - Background and Objectives: The understanding of high body mass index (BMI) and outcomes after Left Ventricular Assist Device (LVAD) implantation continues to evolve and the relationship has not been established yet. In this study, we investigated the effects of obesity (BMI > 30 kg/m2) on post-LVAD implantation outcomes. HeartWare LVAD and Heart Mate III LVAD were implanted. The primary outcome that was measured was mortality (in-hospital and on follow-up). The secondary outcomes that were measured were major adverse events. Materials and Methods: At our institution, the West German Heart and Vascular Center (Essen, Germany), from August 2010 to January 2020, a total of 210 patients received a long-term LVAD. Patients were stratified according to BMI ≥ 30 kg/m2 representing the obesity threshold. The first group (n = 162) had an average BMI of 24.2 kg/m2 (±2.9), and the second group (n = 48) had an average BMI of 33.9 kg/m2 (±3.2). Baseline demographics were analysed alongside comorbidities per group. Results: Overall mortality was not significantly different between the obese group (51.1% n = 24) and the nonobese group (55.2%, n = 85) (p = 0.619). The difference between the mean duration of survival of patients who expired after hospital discharge was insignificant (2.1 years ± 1.6, group 1; 2.6 years ± 1.5, group 2; p = 0.29). In-hospital mortality was unvaried between the two groups: group 1: n = 34 (44% out of overall group 1 deaths); group 2: n = 11 (45.8% out of overall group 2 deaths) (p > 0.05). Postoperative complications were unvaried between the obese and the non-obese group (all with p > 0.05). However, a significant difference was found with regards to follow-up neurological complications (18.5% vs. 37.8%, p = 0.01) and LVAD thrombosis (14.7% vs. 33.3%, p = 0.01), as both were higher in the obese population. Conclusion: Obesity does not form a barrier for LVAD implantation in terms of mortality (in-hospital and on follow up). However, a significantly higher incidence of follow-up LVAD thrombosis and neurological complications has been found in the obese group of patients.
KW - Body Mass Index
KW - Germany
KW - Heart Failure/epidemiology
KW - Heart-Assist Devices/adverse effects
KW - Humans
KW - Obesity/complications
KW - Retrospective Studies
KW - Treatment Outcome
U2 - 10.3390/medicina56110556
DO - 10.3390/medicina56110556
M3 - Article
C2 - 33113962
SN - 1010-660X
VL - 56
JO - Medicina-Lithuania
JF - Medicina-Lithuania
IS - 11
M1 - 556
ER -