Skip to main navigation Skip to search Skip to main content

Severely Thrombosed Transcatheter Aortic Valve 9 Months After Implantation

Research output: Contribution to journalEditorialAcademicpeer-review

Abstract

Bioprosthetic aortic valve thrombosis is a rare complication after transcatheter aortic valve implantation; however, one with a high mortality. We describe the case of a patient with a completely thrombosed transcatheter aortic valve prosthesis 9 months after implantation and review the diagnosis and management of this complication.
Original languageEnglish
Pages (from-to)1441-1444
Number of pages4
JournalAnnals of Thoracic Surgery
Volume100
Issue number4
DOIs
Publication statusPublished - Oct 2015