Skip to main navigation Skip to search Skip to main content

Sensitivity analysis of dose-response model parameters for the bladder in prostate cancer radiotherapy

  • Tanuj Puri*
  • , Tiziana Rancati
  • , Petra Seibold
  • , Adam Webb
  • , Eliana Vasquez Osorio
  • , David Azria
  • , Marie-Pierre Farcy-Jacquet
  • , Jenny Chang-Claude
  • , Alison Dunning
  • , Maarten Lambrecht
  • , Barbara Avuzzi
  • , Dirk de Ruysscher
  • , Elena Sperk
  • , Ana Vega
  • , Liv Veldeman
  • , Barry Rosenstein
  • , Sarah Kerns
  • , Christopher Talbot
  • , Alan Mcwilliam
  • , Peter Hoskin
  • Ananya Choudhury, Catharine West, Marcel van Herk, REQUITE consortium
*Corresponding author for this work

Research output: Contribution to journalArticleAcademicpeer-review

Abstract

Introduction: This study evaluates how model parameter values affect dose-response maps (DRMs) in identifying high-risk bladder subregions associated with late urinary toxicities in prostate cancer patients post-radiotherapy. Methods: Data from 1808 patients were analyzed for five late bladder toxicities. Baseline scores were subtracted from maximum toxicity at 12 and 24 months and dichotomized into grades >= 1 and >= 2. Bladders were segmented on computed tomography scans, and dose-surface maps (DSMs) were created on 91 x 90 voxel grids using spherical and cylindrical coordinates. Voxel doses were converted to equivalent dose in 2 Gy fractions (EQD2, alpha/beta 1-3 Gy). Welch's t and Mann-Whitney U equations were applied at each voxel location. Multiple comparisons were corrected via permutation testing (10-10000 iterations), and statistically significant voxels were identified using the 90th and 95th percentiles of Tmax/Umax. Sensitivity of parameters was assessed by varying one parameter at a time, with changes > 400 voxels (similar to 5% of 8190) classified as large and <= 400 as small. Results: Urinary tract obstruction was the only toxicity significantly associated with bladder DSMs, focusing results on this outcome. After baseline adjustment and dichotomization, event/nonevent counts were 62/701 (grade >= 1) and 21/742 (grade >= 2; N = 763). DRM results showed large effects of toxicity grade threshold, coordinate system, statistical test equation, and Tmax/Umax thresholding. EQD2 alpha/beta showed variable effects, large for cylindrical and small for spherical coordinates, while the number of permutations had only a small effect. Conclusions: Parameter selection significantly influences high-risk subregion identification in DRMs, emphasizing the need for standardized parameter reporting for meaningful external comparisons.
Original languageEnglish
Article number105178
Number of pages13
JournalPhysica Medica: European journal of medical physics
Volume139
DOIs
Publication statusPublished - 1 Nov 2025

Keywords

  • Prostate cancer
  • Radiotherapy
  • Imaging biomarker
  • Prediction model
  • Voxel-based dose-response analysis
  • VBA
  • Image-based data mining
  • IBDM
  • Organ-at-risk
  • OAR
  • Bladder
  • Standardization
  • Multicenter clinical trial
  • Predictive modeling
  • Toxicity
  • RADIATION-THERAPY
  • SURFACE MAPS
  • URINARY TOXICITY
  • RECTAL TOXICITY
  • 68 GY
  • COMPLICATIONS
  • IMPACT
  • COHORT
  • LUNG
  • LONG

Fingerprint

Dive into the research topics of 'Sensitivity analysis of dose-response model parameters for the bladder in prostate cancer radiotherapy'. Together they form a unique fingerprint.

Cite this