Abstract
Introduction: This study evaluates how model parameter values affect dose-response maps (DRMs) in identifying high-risk bladder subregions associated with late urinary toxicities in prostate cancer patients post-radiotherapy. Methods: Data from 1808 patients were analyzed for five late bladder toxicities. Baseline scores were subtracted from maximum toxicity at 12 and 24 months and dichotomized into grades >= 1 and >= 2. Bladders were segmented on computed tomography scans, and dose-surface maps (DSMs) were created on 91 x 90 voxel grids using spherical and cylindrical coordinates. Voxel doses were converted to equivalent dose in 2 Gy fractions (EQD2, alpha/beta 1-3 Gy). Welch's t and Mann-Whitney U equations were applied at each voxel location. Multiple comparisons were corrected via permutation testing (10-10000 iterations), and statistically significant voxels were identified using the 90th and 95th percentiles of Tmax/Umax. Sensitivity of parameters was assessed by varying one parameter at a time, with changes > 400 voxels (similar to 5% of 8190) classified as large and <= 400 as small. Results: Urinary tract obstruction was the only toxicity significantly associated with bladder DSMs, focusing results on this outcome. After baseline adjustment and dichotomization, event/nonevent counts were 62/701 (grade >= 1) and 21/742 (grade >= 2; N = 763). DRM results showed large effects of toxicity grade threshold, coordinate system, statistical test equation, and Tmax/Umax thresholding. EQD2 alpha/beta showed variable effects, large for cylindrical and small for spherical coordinates, while the number of permutations had only a small effect. Conclusions: Parameter selection significantly influences high-risk subregion identification in DRMs, emphasizing the need for standardized parameter reporting for meaningful external comparisons.
| Original language | English |
|---|---|
| Article number | 105178 |
| Number of pages | 13 |
| Journal | Physica Medica: European journal of medical physics |
| Volume | 139 |
| DOIs | |
| Publication status | Published - 1 Nov 2025 |
Keywords
- Prostate cancer
- Radiotherapy
- Imaging biomarker
- Prediction model
- Voxel-based dose-response analysis
- VBA
- Image-based data mining
- IBDM
- Organ-at-risk
- OAR
- Bladder
- Standardization
- Multicenter clinical trial
- Predictive modeling
- Toxicity
- RADIATION-THERAPY
- SURFACE MAPS
- URINARY TOXICITY
- RECTAL TOXICITY
- 68 GY
- COMPLICATIONS
- IMPACT
- COHORT
- LUNG
- LONG
Fingerprint
Dive into the research topics of 'Sensitivity analysis of dose-response model parameters for the bladder in prostate cancer radiotherapy'. Together they form a unique fingerprint.Cite this
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver