T1 - Screening for paroxysmal atrial fibrillation in primary care using Holter monitoring and intermittent, ambulatory single-lead electrocardiography
AU - Karregat, Evert P M
AU - Gurp, Nicole Verbiest-van
AU - Bouwman, Anne C
AU - Uittenbogaart, Steven B
AU - Himmelreich, Jelle C L
AU - Lucassen, Wim A M
AU - Krul, Sebastien P. J.
AU - van Kesteren, Henri A M
AU - Luermans, Justin G L M
AU - van Weert, Henk C P M
AU - Stoffers, Henri E J H
N1 - Copyright © 2021. Published by Elsevier B.V.
PY - 2021/12/15
Y1 - 2021/12/15
N2 - BACKGROUND: Timely detection of atrial fibrillation (AF) is important because of its increased risk of thrombo-embolic events. Single time point screening interventions fall short in detection of paroxysmal AF, which requires prolonged electrocardiographic monitoring, usually using a Holter. However, traditional 24-48 h Holter monitoring is less appropriate for screening purposes because of its low diagnostic yield. Intermittent, ambulatory screening using a single-lead electrocardiogram (1 L-ECG) device can offer a more efficient alternative.METHODS: Primary care patients of ≥65 years participated in an opportunistic screening study for AF. We invited patients with a negative 12 L-ECG to wear a Holter monitor for two weeks and to use a MyDiagnostick 1 L-ECG device thrice daily. We report the yield of paroxysmal AF found by Holter monitoring and calculate the diagnostic accuracy of the 1 L-ECG device's built-in AF detection algorithm with the Holter monitor as reference standard.RESULTS: We included 270 patients, of whom four had AF in a median of 8.0 days of Holter monitoring, a diagnostic yield of 1.5% (95%-CI: 0.4-3.8%). In 205 patients we performed simultaneous 1 L-ECG screening. For diagnosing AF based on the 1 L-ECG device's AF detection algorithm, sensitivity was 66.7% (95%-CI: 9.4-99.2%), specificity 68.8% (95%-CI: 61.9-75.1%), positive predictive value 3.1% (95%-CI: 1.4-6.8%) and negative predictive value 99.3% (95%-CI: 96.6-99.9%).CONCLUSION: We found a low diagnostic yield of paroxysmal AF using Holter monitoring in elderly primary care patients with a negative 12 L-ECG. The diagnostic accuracy of an intermittently, ambulatory used MyDiagnostick 1 L-ECG device as interpreted by its built-in AF detection algorithm is limited.
AB - BACKGROUND: Timely detection of atrial fibrillation (AF) is important because of its increased risk of thrombo-embolic events. Single time point screening interventions fall short in detection of paroxysmal AF, which requires prolonged electrocardiographic monitoring, usually using a Holter. However, traditional 24-48 h Holter monitoring is less appropriate for screening purposes because of its low diagnostic yield. Intermittent, ambulatory screening using a single-lead electrocardiogram (1 L-ECG) device can offer a more efficient alternative.METHODS: Primary care patients of ≥65 years participated in an opportunistic screening study for AF. We invited patients with a negative 12 L-ECG to wear a Holter monitor for two weeks and to use a MyDiagnostick 1 L-ECG device thrice daily. We report the yield of paroxysmal AF found by Holter monitoring and calculate the diagnostic accuracy of the 1 L-ECG device's built-in AF detection algorithm with the Holter monitor as reference standard.RESULTS: We included 270 patients, of whom four had AF in a median of 8.0 days of Holter monitoring, a diagnostic yield of 1.5% (95%-CI: 0.4-3.8%). In 205 patients we performed simultaneous 1 L-ECG screening. For diagnosing AF based on the 1 L-ECG device's AF detection algorithm, sensitivity was 66.7% (95%-CI: 9.4-99.2%), specificity 68.8% (95%-CI: 61.9-75.1%), positive predictive value 3.1% (95%-CI: 1.4-6.8%) and negative predictive value 99.3% (95%-CI: 96.6-99.9%).CONCLUSION: We found a low diagnostic yield of paroxysmal AF using Holter monitoring in elderly primary care patients with a negative 12 L-ECG. The diagnostic accuracy of an intermittently, ambulatory used MyDiagnostick 1 L-ECG device as interpreted by its built-in AF detection algorithm is limited.
KW - Atrial fibrillation
KW - Screening
KW - Electrocardiography
KW - Prevalence
KW - Holter monitoring
KW - Diagnostic accuracy
KW - STROKE
KW - RISK
KW - PERFORMANCE
KW - MANAGEMENT
KW - CARDIOLOGY
KW - DEVICES