Robustness of intensity modulated proton treatment of esophageal cancer for anatomical changes and breathing motion

Richard Canters*, Kim van der Klugt, Vicki Trier Taasti, Jeroen Buijsen, Bastiaan Ta, Inge Steenbakkers, Ruud Houben, Gloria Vilches-Freixas, Maaike Berbee

*Corresponding author for this work

Research output: Contribution to journalArticleAcademicpeer-review

Abstract

BACKGROUND AND PURPOSE: In this study, we assessed the robustness of intensity modulated proton therapy (IMPT) in esophageal cancer for anatomical variations during treatment. METHODS: The first sixty esophageal cancer patients, treated clinically with chemoradiotherapy were included. The treatment planning strategy was based on an internal target volume (ITV) approach, where the ITV was created from the clinical target volumes (CTVs) delineated on all phases of a 4DCT. For optimization, a 3 mm isotropic margin was added to the ITV, combined with robust optimization using 5 mm setup and 3 % range uncertainty. Each patient received weekly repeat CTs (reCTs). Robust plan re-evaluation on all reCTs, and a robust dose summation was performed. To assess the factors influencing ITV coverage, a multivariate linear regression analysis was performed. Additionally, clinical adaptations were evaluated. RESULTS: The target coverage was adequate (ITV V94%>98 % on the robust voxel-wise minimum dose) on most reCTs (91 %), and on the summed dose in 92 % of patients. Significant predictors for ITV coverage in the multivariate analysis were diaphragm baseline shift and water equivalent depth (WED) of the ITV in the beam direction. Underdosage of the ITV mainly occurred in week 1 and 4, leading to treatment adaptation of eight patients, all on the first reCT. CONCLUSION: Our IMPT treatment of esophageal cancer is robust for anatomical variations. Adaptation appears to be most effective in the first week of treatment. Diaphragm baseline shifts and WED are predictive factors for ITV underdosage, and should be incorporated in an adaptation protocol.
Original languageEnglish
Article number110409
Number of pages7
JournalRadiotherapy and Oncology
Volume198
Early online date23 Jun 2024
DOIs
Publication statusPublished - Sept 2024

Keywords

  • Anatomical changes
  • Breathing motion
  • Esophagus
  • Intensity modulated proton therapy

Fingerprint

Dive into the research topics of 'Robustness of intensity modulated proton treatment of esophageal cancer for anatomical changes and breathing motion'. Together they form a unique fingerprint.

Cite this