Retinal microvascular diameter, a hypertension-related trait, in ECG-gated vs. non-gated images analyzed by IVAN and SIVA

Fang-Fei Wei, Zhen-Yu Zhang, Thibault Petit, Nicholas Cauwenberghs, Yu-Mei Gu, Lutgarde Thijs, Anke Raaijmakers, Lotte Jacobs, Wen-Yi Yang, Karel Allegaert, Tatiana Kuznetsova, Peter Verhamme, Harry A. J. Struijker-Boudier, Yan Li, Kei Asayama, Jan A. Staessen*

*Corresponding author for this work

Research output: Contribution to journalArticleAcademicpeer-review

Abstract

The diameters of the retinal microvasculature reflect intermediate target organ damage and predict adverse health outcomes. In view of the pulsatility of the cerebral blood flow and refinement of software used for off-line analysis, we assessed the repeatability of retinal microvascular diameters in ECG-gated vs. non-gated images using nonmydriatic retinal photographs (Canon Cr-DGi visualization system) postprocessed by IVAN (Vasculomatic ala Nicola, version 1.1) or SIVA (Singapore I Vessel Assessment, version 3.6). Using these algorithms, we determined the central retinal arteriolar (CRAE) and venular (CRVE) equivalents and their ratio (arteriole-to-venule ratio (AVR)). The estimates of CRAE (mean, 158.5 mu m), CRVE (222.5 mu m) and AVR (0.71) in 10 volunteers were unaffected (P >= 0.059) by ECG gating. We assessed intragrader repeatability by the Bland and Altman approach in 30 participants with non-gated images and 30 with ECG-gated photographs. Repeatability, which was expressed as the percentage of near maximal variability (4-s.d. range), did not improve with ECG gating. Using SIVA, CRAE and CRVE were systematically larger (P = 0.15) compared with IVAN. The differences (IVAN-SIVA) averaged -5.4 mu m for CRAE, -3.9 mu m for CRVE and -0.012 for AVR in the non-gated images and -3.3 mu m, -6.9 mu m and 0.006, respectively, in the ECG-gated photographs. In conclusion, ECG gating does not affect estimates of the retinal microvascular diameters or improve intragrader repeatability. SIVA yields slightly but significantly larger estimates of the retinal arteriolar and venular diameters. Combining historical readings analyzed by IVAN with more recent readings by SIVA is possible only for AVR and is not recommended for either CRAE or CRVE.
Original languageEnglish
Pages (from-to)886-892
JournalHypertension Research
Volume39
Issue number12
DOIs
Publication statusPublished - Dec 2016

Keywords

  • arterioles
  • microcirculation
  • population research
  • repeatability
  • retina
  • venules

Cite this