QRS Area Before and After Upgrading to Cardiac Resynchronization Therapy Is Not Sufficient to Predict Outcome

  • Fenna Daniels
  • , Frederieke Eerenberg
  • , Marielle Kloosterman
  • , Antonius M. W. van Stipdonk
  • , Cheyenne S. L. Chiu
  • , Mathias Meine
  • , Kevin Vernooy
  • , Michiel Rienstra
  • , Alexander H. Maass*
  • *Corresponding author for this work

Research output: Contribution to journal › Article › Academic › peer-review

Abstract

QRS area reflects ventricular electrical dyssynchrony and is a stronger predictor of cardiac resynchronization therapy (CRT) outcome than QRS duration/morphology. Data on QRS area in patients upgraded from right ventricular pacing to CRT are scarce. We investigated whether QRS area and the difference with biventricular paced QRS area (Delta QRS) in CRT-upgraded patients are associated with clinical outcome and echocardiographic response. This retrospective multicenter study included patients upgraded to CRT. Median values were used as a cut-off for (Delta)QRS area. The primary composite outcome was all-cause mortality, heart transplantation or left ventricular assist device. Secondary outcomes were heart failure hospitalization (HFH) and >= 15% reduction in left ventricular end-systolic volume. A total of 303 patients were included (age 69 +/- 11 years, 75% male, 50% ischemic cardiomyopathy). Median LVEF was 26% [25-34]; baseline QRS area was 132 & micro;Vs [97-162], which reduced to 90 & micro;Vs [61-122] with CRT (p < 0.001), with a triangle QRS area of 35 & micro;Vs [1-74]. The primary outcome occurred in 34.3% during 47 +/- 29 months of follow-up without differences between a small or large baseline and triangle QRS area (p = 0.856; p = 0.968). HFH occurred in 9.2% and patients with large triangle QRS area had fewer HFHs (6.7% versus 15.4%, p = 0.012). Baseline QRS area of >132 & micro;Vs was not associated with HFH (p = 0.832), but was a determinant of better echocardiographic response (OR 2.23, 95% CI 1.10-4.50, p = 0.026). triangle QRS area of >35 & micro;Vs was not associated with echocardiographic response (p = 0.203). To conclude, (triangle)QRS area was not associated with the primary outcome in this small cohort of CRT-upgraded patients. However, baseline QRS area of >132 & micro;Vs was associated with echocardiographic response and triangle QRS area of >35 & micro;Vs with fewer HFHs.
Original languageEnglish
Article number331
Number of pages15
JournalJournal of Cardiovascular Development and Disease
Volume13
Issue number7
DOIs
Publication statusPublished - 14 Jul 2026

Keywords

  • paced QRS area
  • delta QRS area
  • upgrade to CRT
  • CRT-responder