Skip to main navigation Skip to search Skip to main content

Post-Market Analysis of the Xenios Console With the Xlung Tubing Kit 230 for Extracorporeal Membrane Oxygenation After Cardiac Surgery

  • Luca Conci*
  • , Anne-Kristin Schaefer
  • , Thomas Schloglhofer
  • , Emilio Osorio-Jaramillo
  • , Amila Kahrovic
  • , Alvaro Perazzo
  • , Marcus Granegger
  • , Daniel Zimpfer
  • , Dominik Wiedemann
  • , Julia Riebandt
  • *Corresponding author for this work

Research output: Contribution to journalArticleAcademicpeer-review

Abstract

Objectives The use of veno-arterial extracorporeal membrane oxygenation (V-A ECMO) has led to an increasing number of devices available on the market. Most studies pay less attention to which devices have been used; therefore, the information on performance for each device is limited. The current study is a comprehensive post-market analysis of all the major functions and adverse events rates of the Xenios console and XLung kit 230 preconfigured ECMO tubing set in post-cardiotomy applications.Methods This retrospective, single-center analysis, conducted between 2017 and 2021, included 47 adult patients who received V-A ECMO support using the Xenios system following cardiac surgery at our institution.Results The Xenios device was found to effectively improve and maintain microcirculation, organ perfusion, gas exchanges, organ function support, and stabilization of the cardiocirculatory system, while maintaining pump performance and stable body core temperature. Device-related adverse events occurred in 28% of patients but resolved in 81% of cases without leaving clinical sequelae. Fewer hemolysis events than reported in the literature were recorded. Every patient experienced at least two patient-related adverse events, but 43% had no relation to the device and 45% resolved without permanent damage.Conclusions The performance of the evaluated device was demonstrated in all key clinical areas, with an adequate safety profile.
Original languageEnglish
Number of pages12
JournalArtificial Organs
DOIs
Publication statusE-pub ahead of print - 2026

Keywords

  • cardiac surgery
  • DRAE
  • ECMO
  • extracorporeal membrane oxygenation
  • performance
  • postcardiotomy
  • post-market
  • PRAE
  • safety
  • Xenios
  • SUPPORT

Fingerprint

Dive into the research topics of 'Post-Market Analysis of the Xenios Console With the Xlung Tubing Kit 230 for Extracorporeal Membrane Oxygenation After Cardiac Surgery'. Together they form a unique fingerprint.

Cite this