Modeling Hepatic Glucose Tracer Kinetics from Isotope Dilution Technique and Deuterium Metabolic Imaging in Post-Bariatric-Surgery and Non-Operated Individuals

  • Alessandro Brunasso*
  • , Chiara Dalla Man
  • , Simone Poli
  • , Jeanine J Prompers
  • , David Herzig
  • , Roland Kreis
  • , Lia Bally
  • , Michele Schiavon*
  • *Corresponding author for this work

Research output: Contribution to journalArticleAcademicpeer-review

Abstract

Despite extensive research on liver metabolism, mathematical models describing hepatic glucose kinetics are currently limited due to the lack of organ-level data. Here, we propose a model of postprandial hepatic glucose kinetics exploiting liver deuterium metabolic imaging (DMI) data combined with plasma isotope dilution analysis in humans. We used data from 10 individuals who had previously undergone Roux-en-Y gastric bypass surgery (RYGB) and 10 healthy controls (HCs). The experimental setting included a labeled oral glucose tolerance test comprising 60 g of [6,6 0- 2H 2]-glucose in combination with liver DMI at 7 T. The hepatic glucose tracer signal was frequently quantified over 150 min, whereas peripheral plasma insulin and glucose tracer concentrations were measured in venous blood. The model was able to describe both liver and peripheral glucose tracer data well and provided estimates of postprandial glucose appearance and disposal in both the liver and the systemic circulation. The model predicted that almost all the ingested glucose had appeared in the liver in RYGB, but not in HC (89.0% vs. 64.0%, P ¼ 0.008) after 150 min, whereas total hepatic disposal (RYGB ¼ 26.4% vs. HC ¼ 29.7%) and first-pass extraction (RYGB ¼ 10.7% vs. HC ¼ 11.4%) were similar between populations. The fraction of glucose eliminated in the periphery was greater in RYGB (49.9% vs. 25.3%, P ¼ 0.003). Finally, no differences were observed in hepatic blood flow and GLUT2 transport rates. Although further studies are needed to validate and extend the model to include endogenous glucose production and disposal, it can be used to quantify parameters, and possibly reveal defects, of hepatic glucose handling.

Original languageEnglish
Pages (from-to)E102-E116
JournalAmerican Journal of Physiology : Endocrinology and Metabolism
Volume329
Issue number1
Early online date26 May 2025
DOIs
Publication statusPublished - Jul 2025

Keywords

  • RYGB
  • deuterium metabolic imaging
  • glucose metabolism
  • liver
  • mathematical modeling

Fingerprint

Dive into the research topics of 'Modeling Hepatic Glucose Tracer Kinetics from Isotope Dilution Technique and Deuterium Metabolic Imaging in Post-Bariatric-Surgery and Non-Operated Individuals'. Together they form a unique fingerprint.

Cite this