Helical Plating Compared with Straight Plating and Nailing for Treatment of Proximal Third Humeral Shaft Fractures-A Biomechanical Study

Torsten Pastor, Ivan Zderic, Tatjana Pastor, Ludmil Drenchev, Hristo Kostov Skulev, Kenneth P van Knegsel, Mark Lenz, Björn-Christian Link, Boyko Gueorguiev*, Frank J P Beeres

*Corresponding author for this work

Research output: Contribution to journalArticleAcademicpeer-review

Abstract

Background and Objectives: The surgical treatment of proximal humeral shaft fractures usually considers application of either long straight plates or intramedullary nails. By being able to spare the rotator cuff and avoid the radial nerve distally, the implementation of helical plates might overcome the downsides of common fixation methods. The aims of the current study were (1) to explore the biomechanical competence of different plate designs and (2) to compare their performance versus the alternative treatment option of using intramedullary nails. Materials and Methods: Twenty-four artificial humeri were assigned to the following four groups for simulation of an unstable proximal humeral shaft fracture and instrumentation: Group 1 (Straight-PHILOS), Group 2 (MULTILOC-Nail), Group 3 (45°-Helical-PHILOS), and Group 4 (90°-Helical-PHILOS). All specimens underwent non-destructive, quasi-static biomechanical testing under loading in axial compression, torsion in internal/external rotation, and pure bending in four directions, accompanied by motion tracking. Results: Axial stiffness/displacement in Group 2 was significantly higher/smaller than in all other groups (p ≤ 0.010). Torsional displacement in Group 2 was significantly bigger than in all other groups (p ≤ 0.017). Significantly smaller coronal plane displacement was identified in Group 2 versus all other groups (p < 0.001) and in Group 4 versus Group 1 (p = 0.022). Significantly bigger sagittal plane displacement was detected in Group 4 versus all other groups (p ≤ 0.024) and in Group 1 versus Group 2 (p < 0.001). Conclusions: Intramedullary nails demonstrated higher axial stiffness and smaller axial interfragmentary movements compared with all investigated plate designs. However, they were associated with bigger torsional movements at the fracture site. Although 90°-helical plates revealed bigger interfragmentary movements in the sagittal plane, they demonstrated improved resistance against displacements in the coronal plane when compared with straight lateral plates. In addition, 45°-helical plates manifested similar biomechanical competence to straight plates and may be considered a valid alternative to the latter from a biomechanical standpoint.

Original languageEnglish
Article number2043
JournalMedicina-Lithuania
Volume59
Issue number11
DOIs
Publication statusPublished - 20 Nov 2023
Externally publishedYes

Keywords

  • Humans
  • Fracture Fixation, Intramedullary/methods
  • Bone Nails
  • Biomechanical Phenomena
  • Fracture Fixation, Internal
  • Humerus
  • Bone Plates

Fingerprint

Dive into the research topics of 'Helical Plating Compared with Straight Plating and Nailing for Treatment of Proximal Third Humeral Shaft Fractures-A Biomechanical Study'. Together they form a unique fingerprint.

Cite this