TY - JOUR
T1 - Focal monopolar pulsed field ablation from within the great cardiac vein for idiopathic premature ventricular contractions after failed radiofrequency ablation
AU - Chaldoupi, Sevasti-Maria
AU - Nissen, Sarah Dalgas
AU - Vriesendorp, Pieter A
AU - Jerltorp, Kezia
AU - Farnir, Florent I P
AU - Linz, Benedikt
AU - Johannessen, Arne
AU - Haugdal, Martin Aar
AU - Luermans, Justin G L M
AU - Saljic, Arnela
AU - Jespersen, Thomas
AU - Hansen, Jim
AU - Linz, Dominik
PY - 2024/7/4
Y1 - 2024/7/4
N2 - BACKGROUND: Idiopathic epicardial premature ventricular contractions (PVCs) originating from the left ventricular summit are difficult to eliminate. OBJECTIVE: To describe feasibility and procedural safety of focal monopolar biphasic pulsed field ablation (F-PFA) from within the great cardiac vein (GCV) for the treatment of idiopathic epicardial PVCs. METHODS: In 4 pigs, F-PFA (CENTAURI, Cardiofocus) was applied from within the GCV followed by macroscopic gross analysis. In 4 patients with previously failed radiofrequency ablation, electroanatomic mapping was used to guide F-PFA from within the GCV and the ventricular outflow tracts. Coronary angiography and optical coherence tomography (OCT) were performed in 2 patients. RESULTS: In pigs, F-PFA from within the GCV (5mm away from the coronary arteries) resulted in myocardial lesions with a maximal depth of 4mm which was associated with non-obstructive transient coronary spasms. In patients, sequential delivery of F-PFA in the ventricular outflow tracts and from within the GCV eliminated the PVCs. During F-PFA delivery from within the GCV with prophylactic nitroglycerin application, coronary angiography showed no coronary spasm when F-PFA was delivered >5mm away from the coronary artery and a transient coronary spasm without changes in a subsequent OCT, when F-PFA was delivered directly on the coronary artery. Intracardiac echo and computer tomography integration was used to monitor F-PFA delivery from within the GCV. There were no immediate or short-term complications. CONCLUSION: Sequential mapping-guided F-PFA from endocardial ventricular outflow tracts and from within the GCV is feasible with a favourable procedural safety profile for the treatment of epicardial PVC.
AB - BACKGROUND: Idiopathic epicardial premature ventricular contractions (PVCs) originating from the left ventricular summit are difficult to eliminate. OBJECTIVE: To describe feasibility and procedural safety of focal monopolar biphasic pulsed field ablation (F-PFA) from within the great cardiac vein (GCV) for the treatment of idiopathic epicardial PVCs. METHODS: In 4 pigs, F-PFA (CENTAURI, Cardiofocus) was applied from within the GCV followed by macroscopic gross analysis. In 4 patients with previously failed radiofrequency ablation, electroanatomic mapping was used to guide F-PFA from within the GCV and the ventricular outflow tracts. Coronary angiography and optical coherence tomography (OCT) were performed in 2 patients. RESULTS: In pigs, F-PFA from within the GCV (5mm away from the coronary arteries) resulted in myocardial lesions with a maximal depth of 4mm which was associated with non-obstructive transient coronary spasms. In patients, sequential delivery of F-PFA in the ventricular outflow tracts and from within the GCV eliminated the PVCs. During F-PFA delivery from within the GCV with prophylactic nitroglycerin application, coronary angiography showed no coronary spasm when F-PFA was delivered >5mm away from the coronary artery and a transient coronary spasm without changes in a subsequent OCT, when F-PFA was delivered directly on the coronary artery. Intracardiac echo and computer tomography integration was used to monitor F-PFA delivery from within the GCV. There were no immediate or short-term complications. CONCLUSION: Sequential mapping-guided F-PFA from endocardial ventricular outflow tracts and from within the GCV is feasible with a favourable procedural safety profile for the treatment of epicardial PVC.
KW - Pulsed field ablation
KW - coronary spasm
KW - great cardiac vein
KW - idiopathic premature ventricular contractions
KW - left ventricular summit
U2 - 10.1016/j.hrthm.2024.07.002
DO - 10.1016/j.hrthm.2024.07.002
M3 - Article
SN - 1547-5271
JO - Heart Rhythm
JF - Heart Rhythm
ER -