Efficacy of the New Perilaryngeal Airway (CobraPLA™) Versus the Laryngeal Mask Airway (LMA™) to Improve Oropharyngeal Leak Pressure in Obese and Overweight Patients

Siamak Yaghoobi, Seyed Mohamadreza Abootorabi, Hamid Kayalha, Tom C Van Zundert, Amir H Pakpour

Research output: Contribution to journalArticleAcademicpeer-review

Abstract

BACKGROUND: This study aimed to evaluate the applicability of Cobra perilaryngeal airway (Cobra PLA™) for obese patients under general anesthesia and also to compare the results with those of classic laryngeal mask airway (LMA™).

MATERIALS AND METHODS: Seventy-three overweight and obese patients were included in this study. The patients were randomly assigned to LMA™ or Cobra PLA™ groups. Time required for intubation, successful intubation attempt, airway sealing pressure and incidence of complications including blood staining, sore throat and dysphagia were assessed and noted.

RESULTS: Thirty-six and 37 patients were randomly allocated to LMA™ and Cobra PLA™ groups, respectively. Most patients were males and had Mallampati Class II airway in both groups. The first attempt and overall insertion success for Cobra PLA™ was significantly higher compared to LMA (P<0.05). Airway insertion was more successful (P = 0.027; 94% vs. 77%) with Cobra PLA™. Insertion times were similar with Cobra PLA™ and LMA™ (Cobra PLA™, 29.94±16.35s; LMA™, 27.00±7.88s). The oropharyngeal leak pressure in the Cobra PLA™ group (24.80±0.90 H2O) was significantly higher than that in LMA™ group (19±1 H2O, p<0.001). Sore throat was more frequent in the LMA™ group although it did not reach statistical significance (Fisher's exact test, P = 0.33). Blood staining on airway tube was seen in both groups with a higher incidence in the Cobra PLA™ group (Fisher's Exact test, P = 0.02). Incidence of dysphagia was not different between the two groups.

CONCLUSION: CobraPLA™ was found to be safe with low complications. It provided better airway sealing with high rate of the first insertion success for use in obese and overweight patients. This study recommends the use of CobraPLA™ as a rescue device in emergency situations for obese and overweight patients.

Original languageEnglish
Pages (from-to)42-48
Number of pages7
JournalTanaffos
Volume14
Issue number1
Publication statusPublished - 2015

Cite this