Dual-energy CT quantitative imaging: a comparison study between twin-beam and dual-source CT scanners

Isabel P. Almeida, Lotte E. J. R. Schyns, Michel C. Ollers, Wouter van Elmpt, Katia Parodi, Guillaume Landry, Frank Verhaegen*

*Corresponding author for this work

Research output: Contribution to journalArticleAcademicpeer-review

Original languageEnglish
Pages (from-to)171-179
Number of pages9
JournalMedical Physics
Volume44
Issue number1
DOIs
Publication statusPublished - Jan 2017

Keywords

  • Dual-energy dual-source CT
  • Dual-energy twin-beam CT
  • effective atomic number
  • relative electron density
  • CARLO DOSE CALCULATIONS
  • X-RAY TARGETS
  • TISSUE SEGMENTATION
  • ATOMIC NUMBERS
  • SIMULATION
  • QUALITY
  • IMAGES
  • TUBE

Cite this

Almeida, I. P., Schyns, L. E. J. R., Ollers, M. C., van Elmpt, W., Parodi, K., Landry, G., & Verhaegen, F. (2017). Dual-energy CT quantitative imaging: a comparison study between twin-beam and dual-source CT scanners. Medical Physics, 44(1), 171-179. https://doi.org/10.1002/mp.12000
Almeida, Isabel P. ; Schyns, Lotte E. J. R. ; Ollers, Michel C. ; van Elmpt, Wouter ; Parodi, Katia ; Landry, Guillaume ; Verhaegen, Frank. / Dual-energy CT quantitative imaging : a comparison study between twin-beam and dual-source CT scanners. In: Medical Physics. 2017 ; Vol. 44, No. 1. pp. 171-179.
@article{8243c3318a9047df80353eb75ade4f22,
title = "Dual-energy CT quantitative imaging: a comparison study between twin-beam and dual-source CT scanners",
keywords = "Dual-energy dual-source CT, Dual-energy twin-beam CT, effective atomic number, relative electron density, CARLO DOSE CALCULATIONS, X-RAY TARGETS, TISSUE SEGMENTATION, ATOMIC NUMBERS, SIMULATION, QUALITY, IMAGES, TUBE",
author = "Almeida, {Isabel P.} and Schyns, {Lotte E. J. R.} and Ollers, {Michel C.} and {van Elmpt}, Wouter and Katia Parodi and Guillaume Landry and Frank Verhaegen",
year = "2017",
month = "1",
doi = "10.1002/mp.12000",
language = "English",
volume = "44",
pages = "171--179",
journal = "Medical Physics",
issn = "0094-2405",
publisher = "Wiley",
number = "1",

}

Almeida, IP, Schyns, LEJR, Ollers, MC, van Elmpt, W, Parodi, K, Landry, G & Verhaegen, F 2017, 'Dual-energy CT quantitative imaging: a comparison study between twin-beam and dual-source CT scanners', Medical Physics, vol. 44, no. 1, pp. 171-179. https://doi.org/10.1002/mp.12000

Dual-energy CT quantitative imaging : a comparison study between twin-beam and dual-source CT scanners. / Almeida, Isabel P.; Schyns, Lotte E. J. R.; Ollers, Michel C.; van Elmpt, Wouter; Parodi, Katia; Landry, Guillaume; Verhaegen, Frank.

In: Medical Physics, Vol. 44, No. 1, 01.2017, p. 171-179.

Research output: Contribution to journalArticleAcademicpeer-review

TY - JOUR

T1 - Dual-energy CT quantitative imaging

T2 - a comparison study between twin-beam and dual-source CT scanners

AU - Almeida, Isabel P.

AU - Schyns, Lotte E. J. R.

AU - Ollers, Michel C.

AU - van Elmpt, Wouter

AU - Parodi, Katia

AU - Landry, Guillaume

AU - Verhaegen, Frank

PY - 2017/1

Y1 - 2017/1

KW - Dual-energy dual-source CT

KW - Dual-energy twin-beam CT

KW - effective atomic number

KW - relative electron density

KW - CARLO DOSE CALCULATIONS

KW - X-RAY TARGETS

KW - TISSUE SEGMENTATION

KW - ATOMIC NUMBERS

KW - SIMULATION

KW - QUALITY

KW - IMAGES

KW - TUBE

U2 - 10.1002/mp.12000

DO - 10.1002/mp.12000

M3 - Article

VL - 44

SP - 171

EP - 179

JO - Medical Physics

JF - Medical Physics

SN - 0094-2405

IS - 1

ER -

Almeida IP, Schyns LEJR, Ollers MC, van Elmpt W, Parodi K, Landry G et al. Dual-energy CT quantitative imaging: a comparison study between twin-beam and dual-source CT scanners. Medical Physics. 2017 Jan;44(1):171-179. https://doi.org/10.1002/mp.12000