Critical but commonly neglected factors that affect contrast medium administration in CT

Michael C McDermott*, Joachim E Wildberger, Kyongtae T Bae

*Corresponding author for this work

Research output: Contribution to journal(Systematic) Review article peer-review

Abstract

Objective: Past decades of research into contrast media injections and optimization thereof in radiology clinics have focused on scan acquisition parameters, patient-related factors, and contrast injection protocol variables. In this review, evidence is provided that a fourth bucket of crucial variables has been missed which account for previously unexplained phenomena and higher-than-expected variability in data. We propose how these critical factors should be considered and implemented in the contrast-medium administration protocols to optimize contrast enhancement. Methods: This article leverages a combination of methodologies for uncovering and quantifying confounding variables associated with or affecting the contrast-medium injection. Engineering benchtop equipment such as Coriolis flow meters, pressure transducers, and volumetric measurement devices are combined with small, targeted systematic evaluations querying operators, equipment, and the physics and fluid dynamics that make a seemingly simple task of injecting fluid into a patient a complex and non-linear endeavor. Results: Evidence is presented around seven key factors affecting the contrast-medium injection including a new way of selecting optimal IV catheters, degraded performance from longer tubing sets, variability associated with the mechanical injection system technology, common operator errors, fluids exchanging places stealthily based on gravity and density, wasted contrast media and inefficient saline flushes, as well as variability in the injected flow rate vs. theoretical expectations. Conclusion: There remain several critical, but not commonly known, sources of error associated with contrast-medium injections. Elimination of these hidden sources of error where possible can bring immediate benefits and help to drive standardized and optimized contrast-media injections. Critical relevance statement: This review brings to light the commonly neglected/unknown factors negatively impacting contrast-medium injections and provides recommendations that can result in patient benefits, quality improvements, sustainability increases, and financial benefits by enabling otherwise unachievable optimization. Key Points: How IV contrast media is administered is a rarely considered source of CT imaging variability. IV catheter selection, tubing length, injection systems, and insufficient flushing can result in unintended variability. These findings can be immediately addressed to improve standardization in contrast-enhanced CT imaging. Graphical Abstract: (Figure presented.).

Original languageEnglish
Article number219
Number of pages14
JournalInsights into Imaging
Volume15
Issue number1
DOIs
Publication statusPublished - 28 Aug 2024

Keywords

  • Computed tomography
  • Contrast media
  • Injection systems
  • Injections
  • Intravenous

Fingerprint

Dive into the research topics of 'Critical but commonly neglected factors that affect contrast medium administration in CT'. Together they form a unique fingerprint.

Cite this