Skip to main navigation Skip to search Skip to main content

Assessment of the extremity exposure during preparation and administration of <SUP>177</SUP>Lu - results of a multi-center study

  • Robert Kollaard*
  • , Lukasz Albiniak
  • , Nicolas Cherbuin
  • , Jeremie Dabin
  • , Hanan Datz
  • , Mahila Ferrari
  • , Mikko Hakulinen
  • , Sigalit Haruz-Waschitz
  • , Tereza Kracmerova
  • , Ann McCann
  • , Roel Wierts
  • , Alessandra Zorz
  • , Else Aalbersberg
  • *Corresponding author for this work

Research output: Contribution to journalArticleAcademicpeer-review

Abstract

Despite the increased use of Lu-177 in nuclear medicine (NM) over the last 10 years, the knowledge of the actual exposure of the extremities due to manipulation of this pharmaceutical is limited. The purpose of this study is to assess the extremity dose during the preparation and administration of Lu-177-labelled radiopharmaceuticals in a wide range of NM practices. Workers in 10 NM centres throughout Europe wore a ring dosimeter on the base of the index finger of the non-dominant hand during preparation and/or administration of Lu-177-labelled radiopharmaceuticals. Information on manipulated activity, tasks performed and protection measures was collected to allow sub-analyses. The median ring dose per monitoring interval was 0.16 mSv, with a maximum of 2.27 mSv in one month. The median normalised dose amounted 3.5 & micro;Sv GBq(-1) (range 0.5-525). The highest monthly doses were found for workers involved in preparation of the pharmaceutical. The workers performing manual administrations (6.5 & micro;Sv GBq(-1)) showed higher normalised ring doses than those using the gravity method (3.5 & micro;Sv GBq(-1)) or a syringe pump (1.0 & micro;Sv GBq(-1)). Explanations for the wide range of normalised ring doses may be found in the different techniques applied in this study and the differences in minimum reportable doses of the dosimeters. When the data is extrapolated using a fingertip to ring dose ratio of 5, an annual fingertip dose of 1-136 mSv is found, with a median fingertip dose of 10 mSv per year. Extremity exposure during Lu-177 handling remained well below dose limits. The highest normalised doses occurred during preparation and manual administration. Overall, this investigation shows doses remain low when appropriate radiation protection measures (e.g. shielding and minimising time at short distance) are being applied.
Original languageEnglish
Article number031504
Number of pages11
JournalJournal of Radiological Protection
Volume46
Issue number3
DOIs
Publication statusPublished - 1 Sept 2026

Keywords

  • occupational exposure
  • extremity dose
  • administration methods
  • Lu-177
  • H-p(0.07)
  • THERAPY

Fingerprint

Dive into the research topics of 'Assessment of the extremity exposure during preparation and administration of <SUP>177</SUP>Lu - results of a multi-center study'. Together they form a unique fingerprint.

Cite this