A Randomized Multicenter Clinical Trial of Ultrathin Descemet Stripping Automated Endothelial Keratoplasty (DSAEK) versus DSAEK

Mor M. Dickman*, Pieter J. Kruit, Lies Remeijer, Jeroen van Rooij, Allegonda Van der Lelij, Robert H. J. Wijdh, Frank J. H. M. van den Biggelaar, Tos T. J. M. Berendschot, Rudy M. M. A. Nuijts

*Corresponding author for this work

Research output: Contribution to journalArticleAcademicpeer-review

Abstract

Objective: To compare visual acuity, refraction, endothelial cell density (ECD), and complications after Descemet stripping automated endothelial keratoplasty (DSAEK) and ultrathin DSAEK (UT-DSAEK). Design: A multicenter, prospective, double-masked, randomized, controlled clinical trial. Participants: From 66 patients with irreversible corneal endothelial dysfunction dues to Fuchs' dystrophy who enrolled from 4 tertiary medical centers in the Netherlands, 66 eyes were studied. Methods: Participants were centrally randomized to undergo either UT-DSAEK or DSAEK, based on pre-operative best spectacle-corrected visual acuity (BSCVA), recipient central corneal thickness, patient age, and recruitment center. Donor corneas were precut by a single cornea bank. Participants: Participants underwent ophthalmic examinations preoperatively and 3, 6, and 12 months after the operation, including manifest refraction, BSCVA using an Early Treatment Diabetic Retinopathy Study chart, and endothelium imaging. Main Outcome Measures: BSCVA 12 months postoperatively. Results: Preoperative BSCVA did not differ between patients undergoing DSAEK (0.35 logarithm of the minimum angle of resolution [logMAR] [95% confidence interval {CI} 0.27-0.43]; n = 32) and UT-DSAEK (0.37 logMAR [95% CI 0.31-0.43]; n = 34; P = 0.8). BSCVA was significantly better after UT-DSAEK compared with that after DSAEK at 3 months (0.17 logMAR [95% CI 0.13-0.21], n = 31 vs. 0.28 logMAR [95% CI 0.23-0.33], n = 31; P = 0.001), 6 months (0.14 logMAR [95% CI 0.10-0.18], n = 30 vs. 0.24 logMAR [95% CI 0.20-0.28], n = 30; P = 0.002), and 12 months (0.13 logMAR [95% CI 0.09-0.17], n = 33 vs. 0.20 logMAR [95% CI 0.15-0.25], n = 29; P = 0.03). Refraction, ECD loss (40% at 3 months; P <0.001), donor loss (DSAEK n = 2 vs. UT-DSAEK n = 3 [relative risk {RR} 1.4 {95% CI 0.24-7.5}; P = 0.7]), and graft dislocation (DSAEK n = 5 vs. UT-DSAEK n = 5 [RR 1.0 {95% CI 0.34-3.33}; P = 0.9]) did not differ between UT-DSAEK and DSAEK. Donor thickness was significantly thinner for UT-DSAEK (101 mu m [95% CI 93-110 mu m]; range 50-145 mu m) than for DSAEK (209 mu m [95% CI 196-222 mu m]; range 147-289 mu m; P <0.001). Conclusions: This study indicates that compared with DSAEK, UT-DSAEK results in faster and better recovery of BSCVA with similar refractive outcomes, endothelial cell loss, and incidence of complications.
Original languageEnglish
Pages (from-to)2276-2284
JournalOphthalmology
Volume123
Issue number11
DOIs
Publication statusPublished - Nov 2016

Cite this