T1 - Glucose Variability Assessed with Continuous Glucose Monitoring
T2 - Reliability, Reference Values, and Correlations with Established Glycemic Indices-The Maastricht Study
AU - Foreman, Yuri D.
AU - Brouwers, Martijn C. G. J.
AU - van der Kallen, Carla J. H.
AU - Pagen, Demi M. E.
AU - van Greevenbroek, Marleen M. J.
AU - Henry, Ronald M. A.
AU - Koster, Annemarie
AU - Wesselius, Anke
AU - Schaper, Nicolaas C.
AU - Stehouwer, Coen D. A.
N1 - Funding Information:
The Maastricht Study was supported by the European Regional Development Fund via OP-Zuid, the Province of Limburg, the Dutch Ministry of Economic Affairs (grant 31O.041), Stichting De Weijerhorst (Maastricht, the Netherlands), the Pearl String Initiative Diabetes (Amsterdam, the Netherlands), School for Cardiovascular Diseases (CARIM, Maastricht, the Netherlands), Care and Public Health Research Institute (CAPHRI, Maastricht, the Netherlands), School for Nutrition and Translational Research in Metabolism (NUTRIM, Maastricht, the Netherlands), Stichting Annadal (Maastricht, the Netherlands), Health Foundation Limburg (Maastricht, the Netherlands), and by unrestricted grants from Janssen-Cilag B.V. (Tilburg, the Netherlands), Novo Nordisk Farma B.V. (Alphen aan den Rijn, the Netherlands), Sanofi-Aventis Netherlands B.V. (Gouda, the Netherlands), and Medtronic (Tolochenaz, Switzerland).
Publisher Copyright:
© Copyright 2020, Mary Ann Liebert, Inc., publishers 2020.
PY - 2020/5/1
Y1 - 2020/5/1
N2 - Background: Glucose variability (GV) measured by continuous glucose monitoring (CGM) has become an accepted marker of glycemic control. Nevertheless, several methodological aspects of GV assessment require further study. We, therefore, investigated the minimum number of days needed to reliably measure GV, assessed GV reference values, and studied the correlation of GV with established glycemic indices (i.e., HbA(1c), seven-point oral glucose tolerance test [OGTT]-derived indices). Methods: We used cross-sectional data from The Maastricht Study, an observational population-based cohort enriched with type 2 diabetes. Participants with more than 48 h of CGM (iPro2; Medtronic) were included for analysis (n = 851; age: 60 +/- 9years; 49% women; 23% type 2 diabetes). We used mean sensor glucose (MSG), standard deviation (SD), and coefficient of variation (CV) as CGM-derived indices (the latter two for GV quantification). We calculated reliability using the Spearman-Brown prophecy formula, established reference values by calculating 2.5th-97.5th percentiles, and studied correlations using Spearman's rho. Results: Sufficient reliability (R > 0.80) was achieved with two (MSG and SD), or three monitoring days (CV). The reference ranges, assessed in individuals with normal glucose metabolism (n = 470), were 90.5-120.6 mg/dL (MSG), 7.9-24.8 mg/dL (SD), and 7.74%-22.45% (CV). For MSG, the strongest correlation was found with fasting plasma glucose (rho = 0.65 [0.61; 0.69]); for SD, with the 1-h OGTT value (rho = 0.61 [0.56; 0.65]); and for CV, with both the incremental glucose peak (IGP) during the OGTT (rho = 0.50 [0.45; 0.55]) and the 1-h OGTT value (rho = 0.50 [0.45; 0.55]). Conclusions: The reliability findings and reference values are relevant for studies that aim to investigate CGM-measured GV. One-hour OGTT and IGP values can be used as GV indices when CGM is unavailable.
AB - Background: Glucose variability (GV) measured by continuous glucose monitoring (CGM) has become an accepted marker of glycemic control. Nevertheless, several methodological aspects of GV assessment require further study. We, therefore, investigated the minimum number of days needed to reliably measure GV, assessed GV reference values, and studied the correlation of GV with established glycemic indices (i.e., HbA(1c), seven-point oral glucose tolerance test [OGTT]-derived indices). Methods: We used cross-sectional data from The Maastricht Study, an observational population-based cohort enriched with type 2 diabetes. Participants with more than 48 h of CGM (iPro2; Medtronic) were included for analysis (n = 851; age: 60 +/- 9years; 49% women; 23% type 2 diabetes). We used mean sensor glucose (MSG), standard deviation (SD), and coefficient of variation (CV) as CGM-derived indices (the latter two for GV quantification). We calculated reliability using the Spearman-Brown prophecy formula, established reference values by calculating 2.5th-97.5th percentiles, and studied correlations using Spearman's rho. Results: Sufficient reliability (R > 0.80) was achieved with two (MSG and SD), or three monitoring days (CV). The reference ranges, assessed in individuals with normal glucose metabolism (n = 470), were 90.5-120.6 mg/dL (MSG), 7.9-24.8 mg/dL (SD), and 7.74%-22.45% (CV). For MSG, the strongest correlation was found with fasting plasma glucose (rho = 0.65 [0.61; 0.69]); for SD, with the 1-h OGTT value (rho = 0.61 [0.56; 0.65]); and for CV, with both the incremental glucose peak (IGP) during the OGTT (rho = 0.50 [0.45; 0.55]) and the 1-h OGTT value (rho = 0.50 [0.45; 0.55]). Conclusions: The reliability findings and reference values are relevant for studies that aim to investigate CGM-measured GV. One-hour OGTT and IGP values can be used as GV indices when CGM is unavailable.
KW - Continuous glucose monitoring
KW - Epidemiology
KW - Glucose variability
KW - Oral glucose tolerance test
KW - Reference values
KW - Reliability
KW - Type 2 diabetes mellitus